Dual-Beam Infrared Spectrophotometer
|
| |
| |
|
|
| |
| Features |
High quality thermocouple |
Low stray light |
High accuracy measurement |
Simple structure with easy operation |
| |
|
| Introduction |
Infrared spectroscopy is one of the most powerful techniques for identifying organic substances in organic and analytical chemistry. Infrared analysis can be both qualitative and quantitative. LIIR-100 is an important tool in analytical laboratories.
LIIR-100 Dual-Beam Infrared Spectrophotometer can be used to record the IR absorption and reflectance spectra of substances in the spectral range of 4000 ~ 400 cm-1. It is a powerful tool to analyze sample structures in the fields such as petroleum, chemical engineering, pharmacy, public health and environmental protection.
The Windows application software provides a user-friendly interface for the control of the spectrophotometer, data acquisition, and spectral analysis with functions listed below:
● Spectral background baseline memory
● Spectral background baseline correction
● Spectral data smoothing operation
● Spectral baseline slope correction
● Spectral data differential operation
● Spectral data arithmetic operation
● Spectral data accumulating operation
● Conversion of %T and Abs
● Spectrum file management
● Spectral peak search
● Spectrum scale extension
● Spectral absorption expansion |
| |
| Specifications |
Wavenumber Range |
4000 - 400 cm-1 |
Wavenumber Accuracy |
± 4 cm-1 (4000 ~ 2000 cm-1), ± 2 cm-1 (2000 ~ 400 cm-1) |
Resolution |
1.5 cm-1 at 1000 cm-1 |
Transmittance Accuracy |
± 0.2%T (noise level not included) |
I0 Line Flatness and Straightness |
± 2%T |
Stray Light |
≤ 0.5%T (4000~ 650 cm-1), ≤ 1%T (650~ 400 cm-1) |
Abscissa Extension |
×0.5, ×1, ×2, ×5 and ×10 |
Ordinate Extension |
×0.25 to ×50 |
Measurement Mode |
Transmittance, absorbance and single beam |
Scanning Speed |
5 selections (a few minutes to 20 minutes for a scan of full range) |
Slit Width |
5 settings (very wide, wide,
medium, narrow and very narrow) |
Response Time |
5 scales (very fast, fast, medium, slow and very slow ) |
Scanning Mode |
3 modes: continuous, repeated and
specified wavelength |
Electric Power |
110-220 V AC, 50-60 Hz |
|
| |
| Parts List |
| Description |
Qty |
LIIR-100 Dual-Beam Infrared Spectrophotometer |
1 |
Software CD |
1 |
| Files |
User' s Guide |
1 |
Acceptance Certificate |
1 |
Packing List |
1 |
| Accessories |
Polystyrene Film |
1 |
Power Cord |
1 |
Junction Cable |
1 |
Fuse 3 A, 5×30 |
3 |
| Tools |
Crossed Screwdriver (150×5 mm) |
1 |
Flat Screwdriver (75×5 mm) |
1 |
Internal Hexagonal Wrench (2 mm) |
1 |
Internal Hexagonal Wrench (3 mm) |
1 |
Internal Hexagonal Wrench (1.5 mm) |
1 |
|
| |